Product Details:

Place of Origin: China
Brand Name: QIYAO
Certification: ISO, ASME

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: Customized Product, Quoted Case By Case
Packaging Details: Seaworthy packing
Delivery Time: 120 days
Payment Terms: T/T, L/C
Supply Ability: 20 sets per year
Contact Now
Detailed Product Description
Material: Carbon Steel, Stainless Steel Application: For Vapor Recovery Of Highly Volatile Liquid During Loading/unloading Process
Efficiency: Over 97% Valuable Composition In The Vapor Can Be Recovered Service: Design, Engineering & Supply With Site Supervision
Customized: Available
High Light:

flare gas recovery system

,

vapour recovery system

Adsorption - Absorption Type Voc Treatment System Vapor Recovery Unit Design

 

Adsorption-Absorption Type Vapor Recovery Unit

 

* Summary

 

Vapor Recovery Unit is to collect the organic vapor discharged during the manufacturing, storage, loading and unloading processes of various industries and recycle it by means of condensation, adsorption, absorption, membrane separation, etc. so as to finally satisfy the emission standards and create certain economic benefits for the end user.

 

The oil vapor handled by adsorbent will satisfy the emission standard and be discharged directly. The organics separated will be adsorbed and enriched in the adsorbent. When the adsorbent is nearly saturated, vacuum will be created to have the oil vapor adsorbed released from the adsorbent. The oil vapor released will be absorbed by liquid oil spray and then returned to the product oil tank or raw material tank for the purpose of oil vapor recovery.

 

Adsorption process is ideal for the oil vapor of low concentration. The emission after treatment can satisfy stringent national or local standards. The Adsorption-Absorption Process is featured by reduced investment, easy operation, high recovery efficiency and low energy consumption.

 

Principle / Flow Procedure

Taking advantage of different bonding force between the various compositions and the adsorbent, the adsorption process can first separate those difficult to be adsorbed from the others and then the organics apt to be adsorbed get enriched in the adsorbent. Clean emission after treatment then is directly discharged into the atmosphere. When the absorbent is nearly saturated, a vacuum atmosphere will be created in the adsorption tank by a dry screw vacuum pump so that the compositions collected in it vaporize and escape. The oil vapor released is then led to the absorption tower and caught in the absorbent. The liquid oil recovered can be delivered to the product tank or raw material tank requiring no further separation and purification. The absorbent SMDERI uses is the coal based dedicated activated carbon of oil vapor.

 

 

Structure & Parameter (typical project)

Application Vapor recovery
Equipment name Vapor Recovery Unit
Model QY/VR series
Capacity 50-5000 m3/h
Structure Skid-mounted
Material Carbon steel
Fabrication code GB150.1~4-2011
Design code

GB50759-2012

Q/SH0117-2007

Design pressure Micro positive pressure
Design temperature Ambient
Applicable exhaust gas Low/medium concentration oil vapor
Absorption tower Atmospheric pressure packed tower
Packing High efficiency structured packing
Control method PLC automatic control
Main measuring points Pressure signal, level signal, flow signal, temperature signal
Main interlocked alarm system Pressure signal for interlocked blower start-up/shut down; Level signal for interlocked drain pump start-up/shut down; Flow signal to control opening of absorbent liquid valve; Temperature alarm for interlocked emergency shut down; Concentration alarm of flammable or toxic gas
Connection Bolted
Seal Flange
Utility consumption

Instrument air ≤10Nm3/h

Absorbent liquid relevant to capacity

Emission

Benzene ≤ 4mg/m3,

Toluene ≤ 15mg/m3,

Xylene ≤ 20mg/m3,

Ethylbenzene ≤ 100mg/m3,

Acetonitrile ≤ 50mg/m3;

Non-methane total hydrocarbons:

- Removal rate ≥ 97%,

Concentration of emission ≤ 120mg/m3

Noise ≤ 85dB (A)
Stack height 15 m
Service life 25 years
Activated carbon life 8 years
Spare parts 2 years
Warranty 12 months since start-up or 18 months since arrival of equipment
Scope of work / service Full equipment package, supervision for site installation & commissioning, training for operation
Response upon request Within 12 hrs
Project owner Youyue Storage (Shanghai) Co., Ltd.

 

 

 

Advantage

1) Software: ASPEN for process calculation, SW6 for equipment calculation, CADworx for design of          the skid;

2) Started R&D since 2007, built a test platform, accumulated plenty of analysis and research data;

3) Built projects are compliant with current emission standard. Plenty of project experience;

4) 3 tanks + 2 stage adsorption, the exhaust gas meets the emission standard;

5) Automatic switchover between adsorption and desorption;

6) Multi point of temperature monitor for adsorption tank, equipment safety is assured;

7) Dry screw vacuum pump used for desorption, high vacuum degree, no contamination of oil or              water, wear free operation;

8) High efficiency structured packing and low consumption of absorbent;

9) Delivered as a skid to reduce site installation work;

10) Fully sealed blower and flanged connection in the skid to achieve zero leakage;

      11) ExdIIBT4 or ExdIICT4 explosion proof.

 

 

Applied data for an typical project

---- Concentration of emission: Compliance with GB31570-2015 <Standard of pollutant emission           for oil refinery industry>, GB31571-2015 <Standard of pollutant for petrochemical industry> and           the related local standard.

---- Details:

      Benzene ≤ 4mg/m3,

      Toluene ≤ 15mg/m3,

      Xylene ≤ 20mg/m3,

      Ethylbenzene ≤ 100mg/m3,

      Acetonitrile ≤ 50mg/m3;

      Non-methane total hydrocarbons:

- Removal rate ≥ 97%,

- Concentration of emission ≤ 120mg/m3;

      Noise (1m from VRU): ≤ 85dB (A)

      Height of exhaust port: ≥ 15m.

 

Adsorption - Absorption Type Voc Treatment System Vapor Recovery Unit Design

Adsorption - Absorption Type Voc Treatment System Vapor Recovery Unit Design

 

Contact Details
Shanghai Marine Diesel Engine Research Institute

Contact Person: Mrs. Tan Ling

Tel: 86-21-51151156

Fax: 86-21-51711742

Send your inquiry directly to us (0 / 3000)

Other Products