Place of Origin: | China |
Brand Name: | QIYAO |
Certification: | ISO |
Minimum Order Quantity: | 1 set |
---|---|
Price: | Customized Product, Quoted Case By Case |
Packaging Details: | Seaworthy Packing |
Delivery Time: | 4~8 months after PO |
Material: | Carbon Steel, Stainless Steel | Packing: | Seaworthy Packing |
---|---|---|---|
Service: | Design, Supply With Supervision On Site Installation, Commisioning & Training | Application: | Refineries, Petrochemical Industries, Etc. |
Function: | To Produce Superheated Steam Without Fuel Consumption | Environment Impact: | Friendly Emission: Low NOx, SOx & Catalyst Dust |
Customised: | Available | ||
High Light: | air preheater design,combustion air preheater |
Carbon Steel S S Air Preheater In Boiler With Heat Transfer Tube Bundle
Water-Heat-Medium technology
The water-heat-medium technology mainly functions to further recover the heat in low temperature flue gas while make sure that no corrosion is caused at the equipment so as to maximize the energy saving and minimize the energy consumption.
Work Principle/Flow
* The water-heat-medium system mainly consists of flue gas heat exchanger, medium heat exchanger (air preheater, feedwater preheater or other medium preheater), hot water circulation pump, regulating valve set and etc. The flue gas heat exchanger is located at the flue duct at the tail of heating furnace or boiler and the medium heat exchanger is located at the flow path of the medium to be heated.
* The water-heat-medium system uses a medium pressure deaerated water (2.5~5.0MPa) to maintain the operating pressure of the system and improve the saturation temperature of the heat medium water, which is helpful to improve the heat transfer grade and maximize the waste heat recovery process. During normal operation, water-heat-medium system itself does not consume any deaerated water.
* The hot water circulation pump functions to overcome the flow resistance of water-heat-medium system and continuously transfer the heat absorbed by the heat medium water in the flue gas heat exchanger to the medium to be heated. The bypass regulator valve is to regulate the inlet temperature of heat medium water at the flue gas heat exchanger inlet and make sure it is above the flue gas dew point temperature.
Heat medium water flow
Process flow of water-heat-medium system
Structure & Parameter
Service | Waste heat recovery |
Equipment | Non-corrosion water-heat-medium preheater technology |
Specification | Integral modularized structure |
Components | Flue gas heat exchanger, medium heat exchanger (air preheater, feedwater preheater or other medium preheater), hot water circulation pump, regulator valve |
Material | Shell: Q235B |
Fabrication code | Steam boiler safety & technology supervision regulation |
Flue gas flow | Min.: 5000Nm3/h |
Inlet flue gas pressure | -5.0-10.0Kpa |
Inlet flue gas temperature | 200-500℃ |
Outlet flue gas pressure | -4.0-9.0Kpa |
Outlet flue gas temperature | 120℃-150℃ |
Refractory lining | Aluminum silicate fibre felt |
External wall temperature of equipment | ≤60℃ |
Utility | 2-Phase power supply: 10Kw |
Main measuring points | Inlet flue gas temperature |
Main interlocked alarm | nlet flue gas temperature high |
Service life of critical equipment | Design service life: 8 years |
Downtime of spare parts | 3~4 months |
Warranty period | 12 months since normal operation or 18 months since delivery to site, whichever comes first |
Scope of work/service | EPC |
Response to service request | 24hs |
Application | Oil refining, chemical and coal chemical industries |
Advantage
(1) Flexible and easy arrangement
(2) Wide adaptability to various fuels
(3) Accommodation of load change
(4) Improved operation safety
(5) Common use for multiple adjacent heaters
(6) Extended service life.
Typical Application
No. | Project | Specification | User | Qty. |
---|---|---|---|---|
1 | 1# & 2# aromatic hydrocarbons hydrogenation cracking heater waste heat recovery system reconstruction | 1# Flue gas flow:11280kg/h | Sinopec Shanghai company | 2 sets |
2 | 1,200,000T/year catalytic plant waste heat recovery | Q179/505-10/79.2-3.82/348 | Shandong Dongming Petrochemical Group | 1 unit |
3 | 2,800,000T/year heavy oil catalytic CO waste heat recovery reconstruction | BQ211/800-42/135-3.82/450 | Sinopec Hainan company | 2 units |
4 | 1,800,000T/year catalytic plant waste heat boiler | BQC235/900-142-3.82/420 | CNPC Fushun company | 1 unit |
5 | 1,800,000T/year catalytic plant waste heat recovery reconstruction | Q310/540-230-3.82/380 | Yanchang Group Yulin Refining & Chemicals Co. Ltd. | 2 units |
High Pressure Liquid Hydraulic Turbo Expander Generator Improved Overall Energy Efficiency
Natural Gas Turbo Expander Generator Set For Power Generation With Residual Pressure
Differential Pressure Turbo Expander Generator Natural Gas Steam Expander
Metal Fiber Surface Special Burners For Utility Boiler , Incinerator
Oil & Gas Industries Special Burners / Acid Gas Burner Can Stabilize Flame
Stainless Steel Special Burners Atomizing Nozzle For MTP Reactor
Industrial Absorption Heat Pump Manufacturers / Absorption Heat Transformer
Carbon Steel Absorption Heat Pump To Recover Low Grade Waste Heat At 15~70 ℃
Temperature Boosting Absorption Heat Pump Low Pressure Steam / Hot Water Driving Energy